RH-Pro9

The Industry's Most Efficient Sterilizer (now in a convenient cabinet-ready size)

A proven advancement in “RapidCycle” sterilization, the RH-Pro9 sterilizer will raise your level of sterilization efficiency in a convenient size! Using Cutting-Edge HVHA (High-Velocity Hot Air) technology, the RH-Pro9 provides the fastest instrument turnaround of any FDA-Cleared sterilization technology. No steam or water means no lengthy drying cycle with longer instrument life free of corrosion.

For Healthcare, the RH-Pro9 can Eliminate Immediate-Use Steam Sterilization, shortened cycles, work-arounds, and Joint Commission scrutiny!

Click the icons below for more information.

Low Temperature Cycles

CPAC has created low-temperature cycles to process devices/instruments that are known or could potentially become degraded by RapidHeat’s standard High-Temperature cycle of 375°F.

RapidHeat Cycle

RapidHeat™ is an advanced thermal sterilization technology circulating high velocity hot air in a sealed chamber at 200 to 300 air exchanges per minute. Start to finish sterilization cycles in as little as 12 minutes!

N95 Decontamination Cycle

In addition to sterilizing your instruments/devices, your RapidHeat™ sterilizer can now decontaminate your N95 masks as well!

RH-Pro Series Overview

Installation & Operation

Low-Temperature Cycle Options

CPAC has created low-temperature cycles to process devices/instruments that are known or could potentially become
degraded by RapidHeat’s standard High-Temperature cycle of 375°F.

  • Allows user to validate and verify 12-log kill sterilization
  • Choice of three low-temperature cycles
  • Eliminates heat-sensitive device concerns
  • Time/temperature profiles equivalent to steam
  • Three temperature cycles: 320°F (160°C), 300°F (149°C), 280°F (138°C)

RapidCycle Sterilization

Unlike traditional Dry Heat, RapidHeat™ is an advanced thermal sterilization technology circulating high velocity hot air in a sealed chamber at 200 to 300 air exchanges per minute.

  • Complete cycle from door closed to door open is 20 minutes for wrapped instruments!
  • No drying time required
  • Easy to use – push button operation

Mask Decontamination Cycle Resolves N95 FFR Mask Shortages

Under FDA’s EUA granted during the recent COVID-19 pandemic, CPAC created a special cycle to decontaminate N95 masks that are in critical shortage.

  • 34-minute cycle @ 175°F
  • Assures mask returns to original user
  • Maintains mask performance/function over multiple cycles
  • No drying or aeration required